Publication:
Optic Nerve Head Parameters in a Turkish Population Over Forty Years of Age

dc.contributor.authorNiyaz, Leyla
dc.contributor.authorYildirim, Nilgun
dc.contributor.authorMusmul, Ahmet
dc.contributor.authorIDYildirim, Nilgun/0000-0001-6266-4951
dc.date.accessioned2020-06-21T13:32:38Z
dc.date.available2020-06-21T13:32:38Z
dc.date.issued2016
dc.departmentOMÜen_US
dc.department-temp[Niyaz, Leyla] Ondokuz Mayis Univ, Dept Ophthalmol, Fac Med, Samsun, Turkey -- [Yildirim, Nilgun] Osmangazi Univ, Dept Ophthalmol, Fac Med, Eskisehir, Turkey -- [Musmul, Ahmet] Osmangazi Univ, Dept Biostat & Med Informat, Fac Med, Eskisehir, Turkey --en_US
dc.description.abstractObjectives: To evaluate the optic disc area and cup area in a normal population over 40 years of age. Materials and Methods: This prospective study was performed in Eskisehir. Fundus photographs were obtained using a nonmydriatic fundus camera. Planimetric measurements of the optic disc and cup area were performed with VK-2 digital imaging software. Optic nerve parameters were then compared between sex and age groups. Results: A total of 3,038 subjects were evaluated. Mean age was 56.6 10.4 years (range 40-91 years). The median disc area of the subjects was 2.87 (2.53-3.23) mm2 in the right eyes and 2.89 (2.55-3.25) mm2 in the left eyes (p<0.001). The median cup area of the subjects was 0.46 mm2 (0.33-0.64 mm2) in the right eyes and 0.44 mm2 (0.33-0.61 mm2) in the left eyes (p<0.001). The differences in disc and cup area between male and female subjects were not statistically significant (p>0.05). Conclusion: We report the normal distribution of disc area and cup area measurements and their association with age and sex.en_US
dc.identifier.doi10.4274/tjo.89847
dc.identifier.endpage178en_US
dc.identifier.issn1300-0659
dc.identifier.issn2147-2661
dc.identifier.issue4en_US
dc.identifier.pmid28058153
dc.identifier.startpage175en_US
dc.identifier.urihttps://doi.org/10.4274/tjo.89847
dc.identifier.urihttps://hdl.handle.net/20.500.12712/13242
dc.identifier.volume46en_US
dc.identifier.wosWOS:000393279900006
dc.language.isoenen_US
dc.publisherTurkish Ophthalmological Socen_US
dc.relation.journalTurk Oftalmoloji Dergisi-Turkish Journal of Ophthalmologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectOptic Discen_US
dc.subjectOptic Cupen_US
dc.subjectDisc Areaen_US
dc.subjectCup Areaen_US
dc.titleOptic Nerve Head Parameters in a Turkish Population Over Forty Years of Ageen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files