• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Fakülteler
  • Diş Hekimliği Fakültesi
  • Endodonti
  • Makale Koleksiyonu
  • View Item
  •   DSpace Home
  • Fakülteler
  • Diş Hekimliği Fakültesi
  • Endodonti
  • Makale Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

North profa, reciproc blue ve rotate döner sistem niti eğelerin ani apikal kurvatürlü kanallarda döngüsel yorgunluk dirençlerinin karşılaştırılması

Thumbnail

View/Open

Tam Metin / Full Text (487.9Kb)

Date

2021

Author

Baş, Gözde
Yüzgüleç, Elçin
Keskin, Cangül
İnan, Uğur

Metadata

Show full item record

Citation

BAŞ G,YÜZGÜLEÇ E,KESKİN C,İNAN U (2021). NORTH PROFA, RECIPROC BLUE VE ROTATE DÖNER SİSTEM NİTİ EĞELERİN ANİ APİKAL KURVATÜRLÜ KANALLARDA DÖNGÜSEL YORGUNLUK DİRENÇLERİNİN KARŞILAŞTIRILMASI. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, 31(2), 215 - 220. Doi: 10.17567/ataunidfd.814137.

Abstract

Bu çalışmanın amacı North Profa RC Blue (25.08), Reciproc Blue (25.08) ve ROTATE (25.06) döner sistem nikel titanyum(NiTi) eğelerin ani apikal kurvatürlü kanallarda ve vücut sıcaklığında döngüsel yorgunluğa bağlı kırılma dirençlerininkarşılaştırılmasıdır.Gereç ve Yöntem: Bu çalışmada on ikişer adet North Profa RC Blue, Reciproc Blue ve ROTATE döner sistem NiTi eğeleri statikmodel döngüsel yorgunluk deney düzeneğinde, 90° kurvatür açısı ve 2 mm kurvatür yarıçapına sahip paslanmaz çelik yapaykanalda ve 37°C’ de kırılıncaya kadar kullanıldı. Eğelerin kırılma zamanı dijital kronometre ile kaydedildi. Kırılan parçalarınuzunlukları dijital kumpas kullanılarak ölçüldü. Kırık yüzeyler kırılma tiplerinin belirlenmesi için taramalı elektron mikroskobu(SEM) ile incelendi. Eğelerin faz transformasyon sıcaklıkları ise diferansiyel taramalı kalorimetre (DSC) cihazında analiz edildi.Normal dağılım gösteren veriler tek yönlü ANOVA ve post hoc Tukey testi ile analiz edildi.Bulgular: North Profa RC Blue ve Reciproc Blue eğelerin döngüsel yorgunluk dirençleri arasında anlamlı bir fark olmadığısaptanırken (p> 0.05) her iki grubun döngüsel yorgunluk dirençleri ROTATE grubundan istatistiksel olarak anlamlı derecedeyüksek bulundu (p<0.05). Kırık yüzeylerden alınan SEM görüntüleri incelenerek aletlerin döngüsel yorgunluk sonucunda kırıldığıdoğrulandı.Sonuç: North Profa RC Blue ve Reciproc Blue eğelerin döngüsel yorgunluk direnci, ROTATE eğelerden daha yüksek bulundu.Eğelerin vücut sıcaklığında hangi fazda bulundukları ve kinematikleri döngüsel yorgunluk direncini etkilemektedir.
 
The aim of this study was to evaluate the cyclic fatigue resistance of North Profa RC Blue, Reciproc Blue and Rotate nickel titanium (NiTi) files in severe apical curvature at intracanal temperature. Material And Methods: In this study, 12 North Profa RC (25.08), 12 Reciproc Blue (25.08) and 12 ROTATE (25.06) rotary system NiTi files were used until fracture occurred, in static model cyclic fatigue testing device which has an artificial stainless steel canal with a 2-mm radius of curvature and a 90° angle of curvature, at an intracanal temperature of 37°C. The time to failure of the files was recorded using a digital chronometer. The lengths of the fractured fragments were measured using a digital caliper. The fractured surfaces of the files were examined under a scanning electron microscope (SEM). Phase transformation temperatures of the files were analyzed by differential scanning calorimeter (DSC) appliance. Normally distributed data were analyzed by one-way ANOVA and Tukey’s Post Hoc test. Results: No statistical difference was found between the cyclic fatigue resistance values of North Profa RC Blue and Reciproc Blue (p> 0.05). On the other hand, cyclic fatigue resistance values of both groups were higher than those of the ROTATE group, which was statistically significant(p<0.05). SEM images taken from fractured surfaces revealed that the files were fractured as a result of cyclic fatigue. Conclusion: Cyclic fatigue resistance values of North Profa RC Blue and Reciproc Blue nickel titanium files was greater than those of the ROTATE nickel titanium files. The phase transformation temperatures of the files at body temperature and their kinematics affect the cyclic fatigue resistance
 

Source

Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi

Volume

31

Issue

2

URI

https://doi.org/10.17567/ataunidfd.814137
https://hdl.handle.net/20.500.12712/33313

Collections

  • Makale Koleksiyonu [6]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [4706]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Ondokuz Mayıs

by OpenAIRE

Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Library || Ondokuz University || OAI-PMH ||

Ondokuz Mayıs University, Samsun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Ondokuz University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.