Proposal of a method for the evaluation of inaccuracy of home sphygmomanometers

Date

2009

Author

Akpolat, Tekin

Metadata

Show full item record

Abstract

Objective There is no formal protocol for evaluating the individual accuracy of home sphygmomanometers. The aims of this study were to propose a method for achieving accuracy in automated home sphygmomanometers and to test the applicability of the defined method. The purposes of this method were to avoid major inaccuracies and to estimate the optimal circumstance for individual accuracy. Methods The method has three stages and sequential measurement of blood pressure is used. The tested devices were categorized into four groups: accurate, acceptable, inaccurate and very inaccurate (major inaccuracy). The defined method takes approximately 10 min (excluding relaxation time) and was tested on three different occasions. Results The application of the method has shown that inaccuracy is a common problem among non-tested devices, that validated devices are superior to those that are non-validated or whose validation status is unknown, that major inaccuracy is common, especially in non-tested devices and that validation does not guarantee individual accuracy. Conclusion A protocol addressing the accuracy of a particular sphygmomanometer in an individual patient is required, and a practical method has been suggested to achieve this. This method can be modified, but the main idea and approach should be preserved unless a better method is proposed. The purchase of validated devices and evaluation of accuracy for the purchased device in an individual patient will improve the monitoring of self-measurement of blood pressure at home. This study addresses device inaccuracy, but errors related to the patient, observer or blood pressure measurement technique should not be underestimated, and strict adherence to the manufacturer's instructions is essential. Blood Press Monit 14:208-215 (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins.

Source

Blood Pressure Monitoring

Volume

14

Issue

5

URI

https://doi.org/10.1097/MBP.0b013e328330d47b
https://hdl.handle.net/20.500.12712/18405

Collections

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Ondokuz Mayıs

by OpenAIRE

Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Library || Ondokuz University || OAI-PMH ||

Ondokuz Mayıs University, Samsun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Ondokuz University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.