• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Findings related to rotational malalignment in tibial fractures treated with reamed intramedullary nailing

Tarih

2014

Yazar

Say, Ferhat
Bulbul, Murat

Üst veri

Tüm öğe kaydını göster

Özet

Rotational malalignment following closed intramedullary nailing of tibial fractures does not attract attention but is a complication which may lead to serious results. This study aimed to present findings related to rotational malalignment from rotational alignment measurements made clinically and with computerised tomography (CT) in patients who had undergone locked intramedullary nailing for tibial fracture. A total of 26 patients (male/female: 23/3) were evaluated after application of reamed locking intramedullary nailing to a diagnosed tibial shaft fracture. The mean age was determined as 37.5 +/- A 15.6 years. Rotational alignment was measured in both lower extremities clinically as thigh-foot angle (TFA) and radiologically with CT. Rotational malalignment was accepted as a more than 10A(0) difference between the two lower extremities. Malrotation was determined at more than 10A(0) from TFA in two (7 %) of 26 patients and from CT in five (19 %) of 26 patients. In three of them, the malrotation was > 15A(0). Of the patients determined with malrotation with CT, it was determined from clinical measurements in 40 %. The mean rotational difference was determined as greater with CT measurement (4.7A degrees A A +/- A 9.5) compared to the TFA (1.1A degrees A A +/- A 5.6) (p < 0.001). No statistically significant relationship was determined between a rotational difference over 10A(0) and the AO fracture type, fracture location and fibula fixation. A significant number of patients treated with intramedullary nailing for a tibial fracture may result in rotational malalignment. To determine rotational malalignment, a thorough clinical evaluation must be made and different kinds of clinical measurements taken and, when suspicions remain, determination should be made by CT.

Kaynak

Archives of Orthopaedic and Trauma Surgery

Cilt

134

Sayı

10

Bağlantı

https://doi.org/10.1007/s00402-014-2052-2
https://hdl.handle.net/20.500.12712/14947

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.