• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

P-Wave Dispersion and Atrial Electromechanical Delay in Patients with Preeclampsia

Date

2015

Author

Inci, Sinan
Nar, Gokay
Aksan, Gokhan
Sipahioglu, Haydar
Soylu, Korhan
Dogan, Ali

Metadata

Show full item record

Abstract

Objectives: To investigate the duration of atrial electromechanical delay (EMD) and left atrial mechanical function in patients with preeclampsia. Materials and Methods: This study included 26 pregnant women with preeclampsia and 24 age-matched pregnant women without preeclampsia (control group). Atrial electromechanical coupling (PA) and intra-atrial and interatrial EMD were measured using tissue Doppler echocardiography. P-wave dispersion (PWD) was measured via 12-lead electrocardiography. All data were analyzed using SPSS v. 15.0 for Windows (SPSS, Inc., Chicago, Ill., USA). Differences in continuous variables between groups were examined using a nonparametric Mann-Whitney U test. Correlation analysis was performed using Spearman's coefficient of correlation. Categorical values were compared using a. 2 test. Results: PA lateral and PA septal durations were significantly longer in the preeclampsia group than in the control group [74.6 +/- 8.1 vs. 62.3 +/- 5.3 ms (p < 0.001) and 59.7 +/- 5.3 vs. 56.2 +/- 4.9 ms (p = 0.005), respectively]. The duration of interatrial EMD and intra-atrial EMD in the pre-eclampsia group was significantly longer than in the control group [25.4 +/ 4.6 vs. 13.2 +/- 3.9 ms (p < 0.001) and 10.5 +/- 1.9 vs. 7.1 +/- 1.2 ms (p < 0.001), respectively]. PWD was significantly higher in patients with preeclampsia (43.1 +/- 9.1 ms) than in the controls (37.6 +/- 7.9 ms; p = 0.008). There was a significant correlation between PWD and interatrial EMD and intra-atrial EMD [r = 0.46 (p < 0.001) and r = 0.39 (p < 0.001), respectively]. Conclusion: The duration of atrial EMD and PWD was prolonged in patients with preeclampsia. (C) 2015 S. Karger AG, Basel

Source

Medical Principles and Practice

Volume

24

Issue

6

URI

https://doi.org/10.1159/000435857
https://hdl.handle.net/20.500.12712/14650

Collections

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • Scopus İndeksli Yayınlar Koleksiyonu [14046]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Ondokuz Mayıs

by OpenAIRE

Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Library || Ondokuz University || OAI-PMH ||

Ondokuz Mayıs University, Samsun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Ondokuz University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.