• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   DSpace Ana Sayfası
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Intraoperative nerve monitoring in thyroid surgery

Tarih

2015

Yazar

Polat, Ayfer Kamali
Lap, Gokhan
Ozbalci, Selcuk
Karabulut, Kagan
Gungor, Bulent
Polat, Cafer
Erzurumlu, Kenan

Üst veri

Tüm öğe kaydını göster

Özet

BACKGROUND: Nerve injury is one of the specific complications of thyroid surgery despite many advances in surgical technique. The recurrent laryngeal nerve (RLN) and the external branch of superior laryngeal nerve are the nerves at risk during thyroid surgery (1). Morbidity related to recurrent laryngeal nerve injury varies from changes in voice quality to severe dyspnea requiring tracheal intubation or tracheostomy. To minimize the risk of nerve injury, intraoperative nerve monitoring (IONM) being suggested as a tool for helping visual control for RLN has gained significant interest in recent years (1,2). We aimed to determine the effectiveness of nerve monitoring during thyroid surgery and to provide a clinical experience. MATERIALS AND METHODS: This study was performed from June 2010 to June 2012. We prospectively evaluated 94 patients who had thyroid surgery with or without nerve monitoring. Of those patients 48 were in monitored group (M) and 46 were in unmonitored group (UM). RESULTS: The mean age was 48 (27-76) in M group and 52 (73-17) in UM There was only one patient had transient hoarseness in M group and also one patient had transient hoarseness in UM group. One each in both groups had persistent hoarseness. No patients experienced airway problem. Operation time was significantly shorter in M group (p<0.001). CONCLUSIONS: Use of a nerve monitoring system does not substitute for careful dissection and visual identification of nerves, but monitoring can assist the surgeon in identifying the RLN anatomic variability and may decrease the operation time during thyroid surgery.

Kaynak

Annali Italiani Di Chirurgia

Cilt

86

Sayı

3

Bağlantı

https://hdl.handle.net/20.500.12712/14352

Koleksiyonlar

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Politika | Rehber | İletişim |

DSpace@Ondokuz Mayıs

by OpenAIRE

Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Politika || Kütüphane || Ondokuz Mayıs Üniversitesi || OAI-PMH ||

Ondokuz Mayıs Üniversitesi, Samsun, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Ondokuz Mayıs Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.