• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   DSpace Home
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A comparison of tandem ring and tandem ovoid treatment as a curative brachytherapy component for cervical cancer

Date

2020

Author

Gursel, Sukriye Bilge
Serarslan, Alparslan
Meydan, Ahmet Deniz
Okumus, Nilgun
Yasayacak, Tenzile

Metadata

Show full item record

Abstract

Purpose: The standard treatment for locally advanced stage cervical cancer is definitive radiotherapy, the quality of which affects both survival and side effects. Brachytherapy is a major component of definitive radiotherapy; it is administered using different techniques and applicators. The purpose of this study was to dosimetrically compare tandem ovoid (T-ovoid) and tandem ring (T-ring) brachytherapy treatments. Material and methods: Both applicator sets were applied to the same 20 patients, and treatment plans were made three-dimensionally (3D), with high-risk clinical target volume (HR-CTV) and organs at risk contoured. The HR-CTV was defined according to post-external magnetic resonance results. The patients with residual tumors not exceeding one-third of the parametrium were included in this study, while patients with larger masses were excluded and received interstitial therapy. The doses were calculated for both plans. Optimization for the HR-CTV was made with the aim that the equivalent dose according to 2 Gy (EQD(2)) of 90% of the HR-CTV (D-90) would be higher than 85 Gy, without exceeding the maximum dose for organs at risk. Then, pairwise dosimetric comparisons were performed. Results: Plans were compared dosimetrically according to the HR-CTV, point A and B doses, and organs at risk. Although the point A and B doses were higher with T-ovoid use, the 3D HR-CTV coverage was statistically better with T-ring application (EQD(2) of HR-CTV D-90: 97.46 Gy for T-ring and 88.44 Gy for T-ovoid; p < 0.0001). In addition, the rectum and bladder doses were statistically lower with T-ring usage (EQD(2) of rectum, 2 cc; T-ring, 63.10 Gy; T-ovoid, 74.99 Gy; p < 0.0001; EQD(2) of bladder, 2 cc; T-ring, 85.26 Gy; T-ovoid, 89.05 Gy; p < 0.0001). Conclusions: In our study with a limited number of samples, T-ring applicator seems to offer better 3D brachytherapy dosimetry for both HR-CTV and nearby organs at risk.

Source

Journal of Contemporary Brachytherapy

Volume

12

Issue

2

URI

https://doi.org/10.5114/jcb.2020.94308
https://hdl.handle.net/20.500.12712/10291

Collections

  • PubMed İndeksli Yayınlar Koleksiyonu [6144]
  • WoS İndeksli Yayınlar Koleksiyonu [12971]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Policy | Guide | Contact |

DSpace@Ondokuz Mayıs

by OpenAIRE

Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Policy || Library || Ondokuz University || OAI-PMH ||

Ondokuz Mayıs University, Samsun, Turkey
If you find any errors in content, please contact:

Creative Commons License
Ondokuz University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@Ondokuz Mayıs:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.